SU PPLEMENTAR Y INFORMATION - Media.nature.com
Azide to 0.1%, and swirled in centrifuge tubes with 1/3 volumes of frozen 133mM EDTA 33% glycerol until thawed, then harvested by centrifugation, washed with cold sterile Debris was pelleted at 10000rpm in a sorvall SS34 rotor for 10 minutes at 4ºC, and the supernatant was precipitated by ... Fetch This Document
Crystalline Arrays Of Membrane-bound Acetylcholine Receptor
Crystalline arrays of membrane-bound acetylcholine receptor ,tubes are labeled with antibodies directed against each of the four, different AcChoR subunit types (10) 7.4). After centrifugation (Sorvall SS34, 6000 rpm, 10 min) the ... Read Full Source
Superspeed Rotors Thermo Scientific SS-34 Rotor SS-34
Superspeed Rotors Thermo Scientific SS-34 rotor SS-34 ro Tor SPecifica ionS Type Fixed Angle SorVall rc-6 SorVall evolution SorVall rc-5 3.0 3.0 GL Pyrex Tubes 03100 50 16 5,000 50,228 10 x 75 Adapter 00364 1 2 places/adapter 1.5 1.5 Conical Microtube 314352H01 100 16 20,500 50,228 11 x ... Retrieve Here
Chlorophyll Breakdown In Senescent Leaves Identification Of ...
Homogenate was centrifuged in a Sorvall SS34 rotor for 3 min at 8000 ^j^^. The green sediment was washed once (resuspension and centrifugation) in. dorf tubes. After centrifugation at 14000 g,^,. for 3 min, tbe supernatant fluid was sucked off and the ... Fetch Doc
Thermo Scientific Sorvall RC6 Plus - Wcac.yale.edu
Maximum rotor speed depends on the rotor, buckets, assemblies, tubes or adapters to be used. Follow the instructions in the rotor instruction manual. Do not use corroded, scratched or cracked rotors, buckets and assemblies. Check that the rotor, buckets and assemblies are free of such abnormalities before operation. ... Access Document
SYSMEX SalesBooklet EN
Tions as the most popular Sorvall™ SS34 rotor. F14-14x50cy max 14000 rpm, 33 746 x g Dedicated solution for 50 mL conical tubes, with adapters for 15 mL or other tubes, for pelleting cells, tissue homogenates, or subcellular separations. T29-8x50 max 29000 rpm, 100 605 x g ... View This Document
The Biotechnology Education Company - EDVOTEK
The Biotechnology Education Company ® • Centrifuge tubes • Small paint brushes • Spectrophotometer (optional, must be capable of measuring 1 ml sample) • Ice bucket and ice • Waterbath in a Sorvall SS34 rotor). 6. Decant the supernatant from step 5 into a clean centrifuge tube ... Read Content
Vivascience Vivaspin 15R - Bio-Rad
50 ml conical bottom tubes. These devices are notdesigned to fit into rotors that only accept round bottom 29 mm x 105 mm tubes, e.g. Sorvall SS34 Beckmann JA 20. If your rotor accepts only 29 mm x 105 mm round bottom tubes, please use the Vivaspin 15, which can be used in either round bottom or conical centrifuge tubes. Operation 1. ... Access Doc
Instructions 28-9331-02 AB
Instructions 28-9331-02 AB Vivaspin 500, 2, 6 and 20 bottom 29 mm + 105 mm tubes, for example: • Sorvall SS34 . 0 2A Jnamk c•Be Vivaspin Centrifuge Minimum rotor angle Rotor cavity Conical bottom tube size 500 Fixed angle 40° 11 mm Ø 2.2 ml ... Document Viewer
Technical Data And Operating Instructions Vivaspin Endotest
With (Heraeus/Sorvall) 75006445 swing out rotor with 75006441 buckets and adaptors for Falcon 50 ml conical bottom tubes. These devices are not designed to fit into rotors that only accept round bottom 29 mm + 105 mm tubes, e.g. Sorvall SS34 Beckman JA 20. ... Content Retrieval
Preparation Of Rough Microsomes From Rat Liver
Refrigerated centrifuge (Sorvall), SS34 rotor, and appropriate tubes Surgical tools Syringe Ultracentrifuge (Beckman Instruments), SW41 and Ti60 rotors, and appropriate tubes METHOD Collection of Fresh Liver 1. Sacrifice an appropriate number of 150-g male rats (Sprague–Dawley) by cervical dislocation and decapitation. 2. ... Doc Retrieval
INSTRUCTION MANUAL - Labmakelaar.com
TUBES, BOTTLES AND ADAPTERS. Each Sorvall Superspeed Angle Rotor accepts a variety of plastic, glass and stainless steel tubes and bottles. Special adapters permit the use of tubes and bottles other than those which fit the basic rotor. ... Fetch Full Source
Superspeed Rotors Thermo Scientific SS-34 Rotor SS-34
SORVALL RC-6 SORVALL Evolution SORVALL RC-5 Plus Series RC Series Plus Series SS-34 Max. Speed 20,000 rpm 20,500 rpm 20,000 rpm Max. RCF 47,808 xg 50,230 xg 47,808 xg 3.0 3.0 GL Pyrex Tubes 03100 50 16 5,000 50,228 10 x 75 Adapter 00364 1 2 places/adapter 1.5 1.5 Conical Microtube 314352H01 ... Doc Viewer
Sorvall Evolution Rc Superspeed Centrifuge Manual
Download Sorvall Evolution Rc Superspeed Centrifuge Manual Pdf you wish to use nonsorvall tubes you must receive permission from stevethe sorvall? evolution? rc super speed refrigerated centrifuge ss34 rotor sorvall rc5b plus high speed floor centrifuge ... Visit Document
Superspeed Rotors Thermo Scientific SS-34 Rotor
Superspeed Rotors Thermo Scientific SS-34 Rotor. ROTOR SPECIFICATIONS Type. Fixed Angle . Material. Aluminum. SORVALL RC-6 SORVALL Evolution SORVALL RC-5 Plus Series RC Series Plus Series 3.0 3.0 GL Pyrex Tubes 03100 50 16 5,000 50,228 10 x 75 Adapter 00364 1 2 places/adapter 1.5 1.5 ... Content Retrieval
Luteovirus Isolation And RNA Extraction - Rd.springer.com
16. Transfer the virus into tubes and centrifuge at 11,950 g in a Sorvall SS34 rotor for 10 min. Carefully remove the supernatant (see Note 6). 17. Layer 1.0 mL of the virus solution onto each of the sucrose gradients. Centrifuge the virus in a Beckman SW41 rotor at 103,300g for 2 h (see Note 7). 18. ... Retrieve Full Source
Part 2 SORVALL SUPERSPEED - Boyce Thompson Institute
TO ORDER, CALL 1-800-522-SPIN (7746) B-19 B-2 SORVALL SUPERSPEED Page SORVALL SUPERSPEED RC-26 Plus RC-5C Plus RC-5B Plus Rotors, Tubes, Bottles, Adapters and Accessories ... Visit Document
Large-Scale Purification Of Virions Using Sarkosyl
The pellet collects at the angle rather than the tip, which makes it particularly easy to free of residual supernatant. If you don’t have this rotor, you can use OakRidge tubes and the Sorvall SS34 rotor (or equivalent Beckman rotor) instead. The capacities of different SW41 ultracentrifuge tubes differ slightly. ... Retrieve Document
Marshall Scientific - Sorvall RC5B Plus Centrifuge With SLA ...
Sorvall RC5B Plus Refrigerated Floor Centrifuge, 21000 rpm, 50000g, -20 to 40 Degrees C with Temperature, Speed and Timer Control. Includes either a SLA 3000 Super Lite 12 rotor or SS34 rotor. ... View Video
Technical Data And Operating Instructions Vivaspin 15R
Sorvall) 75006445 swing out rotor with 75006441 buckets and adaptors for Falcon 50 ml conical bottom tubes. These devices are not designed to fit into rotors that only accept round bottom 29 mm + 105 mm tubes, e.g. Sorvall SS34 Beckman JA 20. If your rotor accepts only 29 mm + 105 mm round bottom tubes, please use the Vivaspin 15, which can be ... Retrieve Content
Technical Data And Operating Instructions Vivaspin Turbo 15
With (Heraeus/Sorvall) 75006445 swing out rotor with 75006441 buckets and adaptors for Falcon 50 ml conical bottom tubes. These devices are not designed to fit into rotors that only accept round bottom 29 mm +105 mm tubes, e.g. Sorvall SS34 or Beckman JA 20. If your rotor accepts only 29 mm +105 mm round bottom tubes, ... Document Retrieval
No comments: